The following chart shows typical dispensing results for contactless "Jet"-Dispensing. The indicated dosing quantities are minimum quantities which can be achieved. Larger dosing quantities can be adjusted with different dispensing parameters, e. g. metering times. The valve used for these tests was the standard valve DV 100. Some dispensing parameters, e. g. feed pressure, may differ using another valve type.
| Medium | Viscosity [mPas] | Feed pressure [MPa] | Metering time [ms] | Distance to substrate [mm] | Valve temperature [Degree Celsius] | Metering quantity [micro litre] |
| Motor oil | SAE 10W-40 | 0.1 | 0.250 | 10 | 50 | 0.070 |
| 1-k acrylate UVB-curing | 165.000 thixotrop | 2.5 | 0.250 | 7 | 40 | 0.030 |
| 1-k silikone heat-curing | 750 | 1 | 0.260 | 10 | 30 | 0.004 |
| 1-k epoxy | 4.000 | 4.2 | 0.250 | 13 | 30 | 0.100 |
| 1-k epoxy | 36.000 thixotropic | 4.6 | 0.250 | 11 | 45 | 0.060 |
| 1-k disperse colour (acrylate based) | 50 | 0.5 | 0.250 | 6 | 30 | 0.002 |
| 1-k acrylate UVB-curing | 80 | 0.6 | 0.260 | 11 | 30 | 0.002 |
| 1-k acrylate heat-curing | 8.000 | 3 | 0.250 | 4 | 30 | 0.006 |